Performance Analysis Of Shunt Active Filter Using Different Controllers

  ijett-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2013 by IJETT Journal
Volume-4 Issue-5                      
Year of Publication : 2013
Authors : K.Sarasvathi , R.Rajalakshmi

Citation 

K.Sarasvathi , R.Rajalakshmi. "Performance Analysis Of Shunt Active Filter Using Different Controllers ". International Journal of Engineering Trends and Technology (IJETT). V4(5):1815-1820 May 2013. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group.

Abstract

In this paper, Performance of Shunt active power filter (SAPF) is analyzed for various types of non linear loads. Among the various control schemes available for SAPF, in direct current control scheme is used here. PI controller and fuzzy logic controller are used to analyze its performance for various types of nonlinear loads (R, DC motor, Induction motor). The output parameters are Total Harmonic Distortion (THD) and p ower factor. The results are obtained with the conventional PI controller and fuzzy controller. The proposed method offer an efficient control method under the various load conditions results in power factor improvement and THD reduction. Simulation of the proposed controller (PI and fuzzy logic controller) of a shunt active power filter has been carri ed out in MATLAB/SIMULINK and the aim is to reduce the THD and improve the power factor.

References

[1] Akagi, H. 1994. Trends in active power line conditioners. IEEE Trans.Power , Electron., vol.9, no.3,pp,263 - 268.
[2] Jaume Miret., and Miguel Castilla., Jose Matlas., Joseph Guerrero, M., and C.Vasquez, C. 2009. Selective Harmonic Compensation Control for Single - phase Active filter with High Harmonic Rejection IEEE Trans on Industrial Electronics,vol.56,No.8,(August 2009).
[3] Bhonsle, D.C., Zaveri, N.K., and Dr.Kelkar, R.B. 2008.Design and Simulation Of Si ngle phase Shunt Active Power Filter for Harmonic mitigation in distribution systemThe International Conference on Electrical Engineering .
[4] Malesani, L., Mattavlli, P., and Busom, S. 1998. On the applications of active Filters to generic loads in Proc. IEEE ICHQP, Athens, Greece, oct.14 - 16, pp.310 - 318.
[5] Suresh Kumar, B., Lalitha, V., and Ramesh Reddy, C. PI, Fuzzy Logic Controlled Shunt Active Power Filter for Three - Phase four wire systems with Balanced, Unbalanced and Variable Loads. Journal of Theor etical and Applied Information Technology.
[6] Wu, J.C., and Jou, H.L. 1996. Simplified control method for single - phase active power filter,”Proc.Inst.Elect.Eng. PowerAppl.,vol.143,no. 3, pp.219 - 224, (May 1996).
[7] Mattaveli, P. A closed – loop selective harmo nic compensation for active filters IEEE Trans. Ind. Appl.,vol. 37, no. 1, pp. 81 - 89, Jan. 2001.
[8] Lenwari, W., Sumner, M., and Zanchetta, P. The use of genetic algorithms for the design of resonant compensators for active filters. IEEE Trans.Ind. Electron. , vol. 56, no. 8,pp.2852 - 2861, (Aug.2009).
[9] Allmeling, J. A control structure for fast harmonics compensation in active filters. IEEE Trans. Power Electron.,vol. 19, no. 2, pp. 508 - 514, (Mar 2004).
[10] Seb asthi Rani, K. , Porkumaran, K. Performance Evaluation of PI and Fuzzy controller based Shunt ActivePower Filter” European Journal of Scientific Research, ISSN 1450 - 216X,Vol.61,No.3(2011).
[11] Sivanandam, S.N., Sumathi, S., and Deepa, S.N. Introduction to F uz zy Logic using MATLAB.

Keywords
Active power filter(APF), Harmonics,Power quality, Selective harmonic compensation