Assessment of a High Voltage Transmission Line with Gaseous Insulation

Assessment of a High Voltage Transmission Line with Gaseous Insulation

  IJETT-book-cover           
  
© 2024 by IJETT Journal
Volume-72 Issue-9
Year of Publication : 2024
Author : Ansari Habiburrahman, M. Murali
DOI : 10.14445/22315381/IJETT-V72I9P127

How to Cite?
Ansari Habiburrahman, M. Murali, "Assessment of a High Voltage Transmission Line with Gaseous Insulation," International Journal of Engineering Trends and Technology, vol. 72, no. 9, pp. 321-326, 2024. Crossref, https://doi.org/10.14445/22315381/IJETT-V72I9P127

Abstract
Electrical Energy is generated at the generating power stations. These generating power stations may be located either near or far away from the load centers. Generally, load centers are away from the generating stations. For power transmission purposes, transmission lines are required, which may be overhead transmission lines or underground cables. In this paper, we only consider air-insulated and gas-insulated transmission systems. For the last forty-five years, another transmission technique has been working in the power system field, which is called the Gas-Induced Transmission Line (GITL). In this research paper, we summarize the results and behavior of the overhead and GITL with different parameters like the length of the transmission line, the transmission line voltage level, etc. For simulation purposes, take one simple 40 Km line with a 220 KV voltage level and show the same result next in the same transmission network with the change in line resistance, inductance, and capacitance, getting the result of a gas-insulated transmission network. Basic voltage regulation and efficiency are observed in this paper. Based on simulation results, we conclude that the most suitable design for a 40 Km short transmission line of 220 KV is GITL. Also presented is the graph of receiving and sending ends voltages for both air-insulated and gas-insulated transmission systems. Although GITL may become our future transmission line based on performance and low losses.

Keywords
High Voltage Gas-Insulated Transmission Line (HV-GITL), Over-Head Transmission Lines (OHTL), Voltage Regulation (VR), Ultra High Voltage Transmission Line (UHV-TL), Aluminium Conductor Steel Reinforced (ACSR), Gas-Insulated Substation (GIS).

References

[1] Abdelhay A. Sallam, and Om P. Malik, Power Flow Analysis, Power System Stability: Modelling, Analysis and Control, pp. 107-130, 2015,
[CrossRef] [Google Scholar] [Publisher Link]
[2] Hermann J. Koch, Gas Insulated Transmission Lines (GIL), Wiley, pp. 1-384, 2011.
[Google Scholar] [Publisher Link]
[3] Ansari Habibur Rahman, and Kishor Bhimrao Gawale, “Optimal Sizing of Conductor and Enclosure for 400 kV Gas Insulated Line,” International Journal for Scientific Research & Development, vol. 3, no. 5, pp. 342-344, 2015.
[Publisher Link]
[4] Roberto Benato, Claudio Di Mario, and Hermann Koch, “High-Capability Applications of Long Gas-Insulated Lines in Structures,” IEEE Transactions on Power Delivery, vol. 22, no. 1, pp. 619-626, 2007.
[CrossRef] [Google Scholar] [Publisher Link]
[5] Tomasz Magier, Andreas Dehler, and Hermann Koch, “AC Compact High Power Gas-Insulated Transmission Lines,” 2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D), Denver, CO, USA, pp. 1-5, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[6] Michael Tenzer, Hermann Koch, and Denis Imamovic, “Compact Systems for High Voltage Direct Current Transmission,” International ETG Congress 2015; Die Energiewende - Blueprints for the New Energy Age, Bonn, Germany, pp. 1-6, 2015.
[Google Scholar] [Publisher Link]
[7] H.J. Koch, “AC Bulk Power Systems in Metropolitan Areas Application,” 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific, Dalian, China, pp. 1-4, 2005.
[CrossRef] [Google Scholar] [Publisher Link]
[8] Danish Khan et al., “Comparison of Transmission Losses and Voltage Drops of GIL(Gas Insulated Transmission Line) and Overhead Transmission Lines,” 2014 16th International Power Electronics and Motion Control Conference and Exposition, Antalya, Turkey, pp. 1151-1153, 2014.
[CrossRef] [Google Scholar] [Publisher Link]
[9] Ansari Habibur Rahman, and Shaikh Muhammad Moinuddin, “Comparision of Voltage Regulation of Gas Insulated Transmission Line and XLPE Cable,” International Journal of Modern Trends in Engineering and Research, vol. 2, no. 4, pp. 269-276, 2015.
[Google Scholar]
[10] R. Benato et al., “Gas Insulated Transmission Lines in Railway Galleries,” IEEE Transactions on Power Delivery, vol. 20, no. 2, pp. 704-709, 2005.
[CrossRef] [Google Scholar] [Publisher Link]
[11] C.G. Henningsen et al., “Electrical and Mechanical Long-Time Behavior of Gas-Insulated Transmission Lines,” CIGRE Session, vol. 8, 2000.
[Google Scholar] [Publisher Link]
[12] Geng Chen et al., “Environment-Friendly Insulating Gases for HVDC Gas-Insulated Transmission Lines,” CSEE Journal of Power and Energy Systems, vol. 7, no. 3, pp. 510-529, 2019.
[CrossRef] [Google Scholar] [Publisher Link]
[13] Hermann Koch et al., “Technical Aspects of Gas Insulated Transmission Lines and Application of New Insulating Gases,” IEEE Transactions on Dielectrics and Electrical Insulation, vol. 25, no. 4, pp. 1448-1453, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[14] K. Elnaddab, A. Haddad, and H. Griffiths, “The Transmission Characteristics of Gas Insulated Lines (GIL) Over Long Distance,” 2012 47th International Universities Power Engineering Conference, Uxbridge, UK, pp. 1-5, 2012.
[CrossRef] [Google Scholar] [Publisher Link]
[15] Sandeep Ushkewar, Gaurav B. Patil, and Vishal Moyal, “Wireless Charging in a Dynamic Environment for Electric Vehicles,” 2022 IEEE Bombay Section Signature Conference, Mumbai, India, pp. 1-5, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[16] H. Shafqat Kharal et al., “Insulation Characteristic of CCl2F2 with Mixtures of CO2/N as a Possible Alternative to SF6 Substitute Gas for High Voltage Equipment’s,” 2018 International Conference on Power Generation Systems and Renewable Energy Technologies, Islamabad, Pakistan, pp. 1-5, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[17] Mohanish Thakur, Aayush Patil, and Gaurav Patil, “The Current State of the Art for PV Grid Connected System Issues with Power Quality,” 2022 International Interdisciplinary Humanitarian Conference for Sustainability (IIHC), Bengaluru, India, pp. 1515-1520, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[18] Rahmat Ullah et al., “Dielectric Properties of Tetrafluoroethane (R134) Gas and its Mixtures with N2 and Air as a Sustainable Alternative to SF6 in High Voltage Applications,” Electric Power Systems Research, vol. 163, pp. 532-537, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[19] Rahmat Ullah et al., “Dielectric Characteristic of Dichlorodifluoromethane (R12) Gas and Mixture with N2/Air as an Alternative to SF6 Gas,” High Voltage, vol. 2, no. 3, pp. 205-210, 2017.
[CrossRef] [Google Scholar] [Publisher Link]
[20] Gaurav B. Patil, Santosh S. Raghuwanshi, and L.D. Arya, “Effect of PV Penetration on the Steady-State Voltage on Grid-Integrated PV System,” Proceedings of Intelligent Communication Technologies and Virtual Mobile Networks, pp. 509-521, 2023.
[CrossRef] [Google Scholar] [Publisher Link]
[21] Kalyani Chavan, Gaurav B. Patil, and Rohini More, “Transient Stability Analysis of IEEE Test System,” 2024 IEEE International Conference for Women in Innovation, Technology & Entrepreneurship, Bangalore, India, pp. 691-695, 2024.
[CrossRef] [Google Scholar] [Publisher Link]
[22] Sandeep Ushkewar, Nilesh Ahire, and Gaurav Patil, “Enhancing Capabilities of Wireless Transmission for Electric Vehicle,” 2022 Global Energy Conference, Batman, Turkey, pp. 278-281, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[23] Hitoshi Okubo, and Abderrahmane Beroual, “Recent Trend and Future Perspectives in Electrical Insulation Techniques in Relation to Sulfur Hexafluoride (SF6) Substitutes for High Voltage Electric Power Equipment,” IEEE Electrical Insulation Magazine, vol. 27, no. 2, pp. 34-42, 2011.
[CrossRef] [Google Scholar] [Publisher Link]
[24] Gaurav B. Patil, and L.D. Arya, “Voltage Stability Assessment of Grid Connected Solar PV System,” 2021 Third International Conference on Intelligent Communication Technologies and Virtual Mobile Networks (ICICV), Tirunelveli, India, pp. 563-568, 2021.
[CrossRef] [Google Scholar] [Publisher Link]
[25] Amit Wani, Prathamesh Mistari, and Gaurav B. Patil, “Comparative Analysis of Power Quality Issues in Grid-Integrated Wind Energy System,” 2022 International Interdisciplinary Humanitarian Conference for Sustainability (IIHC), Bengaluru, India, pp. 1485-1489, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[26] H. Koch, “Optimized Pipeline for Electricity,” IEEE Spectrum, pp. 6-9, 2001.
[Google Scholar]