Abstract
The project is totally based on microcontroller.It uses PIC16F874/77 microcontroller which is based on microchip’s Mid-Rangecore.It uses an IR sensor (The sensor consists of an IR light emitting diode transmitter and an IR photo detector acting as the receiver) which will detect the volume of blood per second passes through the finger. Using this project we can easily find the heartbeat of a person per second without a doctor. The microcontroller check the status of IR sensor and based upon it will send a signal tothe LCD display. This circuit is being tested in protous and in breadboard and is properly working. This project is basically made for use in hospitals and can be used for simple experiments in colleges and schools. It is a cost effecting project, easy to use, reliable and simple.

 References

[1] Mamun, A. L., Ahmed, N., Alqahtani, M., Altwijri, O., Rahman, M., Ahamed,N.U., Rahman, S.A.M.M., Ahmad, R.B., Sundaraj, K. ?A Microcontroller-Based Automatic HeartRate Counting System from Fingertip, School of Computer and Communication Engineering, University Malaysia Perlis, Malaysia.
[2] ]. D. Ibrahim and K. Buruncuk, "Heart Rate Measurement from the Finger Using a Low- Cost Microcontroller," Near East University, Faculty of Engineering, TRN, 2005.
[3] S.Sakuntala and R.RamyaDharshini, ?remote health monitoring system Using pic microcontroller, B.E, ECE, MepcoSchlenk Engineering College, Sivakasi, India. ISSN: 0976-1353 Volume 13 Issue 2 –MARCH 2015.
[4] D.J.R.Kiran Kumar, NaliniKotnana ? Design and Implementation of Portable Health Monitoring system Usingpsoc Mixed Signal Array chip,ISSN: 2277-3878, Volume-1, Issue-3, August 2012.
[5] ] Souvik Das ?The Development of a Microcontroller Based Low- Cost Heart Rate Counter for Health Care Systems, (IJETT)Volume4Issue2- 2013.
[6] ] Chen M, ?The Influence of Resting Heart Rate to Cardiovascular Disease Prognosis , Hainan Medical Journal, 2007.
[7] J. Allen, ?Photoplethysmography and its application in clinical physiological Measurement, Physiological measurement, vol. 28, no. 3, pp.R1–R39, 2007.
[8] Bronzino, Joseph D. (Editor). The Biomedical Engineering Handbook. Boca Raton: CRC Press, Inc., 1995.
[9] Y. C. Eldar and H. Rauhut, ?Average case analysis of multichannel sparse recovery using convex relaxation, Information Theory, IEEETransactions on, vol. 56, no. 1, pp. 505–519, 2010. [10] ] Daniel HE, (Simcom ltd.
[11] V. Jayasree, et al., "Design and DevelopmentOf a Simple Hardware Setup for SensingBlood Volume Pulse and a PICMicrocontroller Based Heart Rate Meter," inBiomedical and Pharmaceutical Engineering,2006. ICBPE 2006. International Conferenceon, 2006, pp. 256- 258.
[12] S. F Babiker, et al., "Microcontroller Based Heart Rate Monitor using Fingertip Sensors,"Khartoum University Engineering Journal, vol.1, 2011.
[13] H. Chatterjee, et al., "A microcontroller basedsystem for real-time heart rate estimation fromECG signal," in India Conference (INDICON),2012 Annual IEEE, 2012, pp. 1020-1025.

Keywords
Microcontroller,Sensor, Biomedical monitoring.