Comparative Performance Evaluation of Evaporative Cooling Local Pad materials with Commercial Pads

  IJETT-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2016 by IJETT Journal
Volume-39 Number-4
Year of Publication : 2016
Authors : K.V.Vala, M.T. Kumpavat, Dr. A. Nema
DOI :  10.14445/22315381/IJETT-V39P234

Citation 

K.V.Vala, M.T. Kumpavat, Dr. A. Nema"Comparative Performance Evaluation of Evaporative Cooling Local Pad materials with Commercial Pads", International Journal of Engineering Trends and Technology (IJETT), V39(4),198-203 September 2016. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group

Abstract
In this study, a special test setup was designed and fabricated to evaluate the performance of different pad materials. The pads were evaluated for their temperature drop, increase in relative humidity inside the storage chamber. For this purpose, the tests were carried out for four different pad materials; CELdek pad, aspen pad, coconut coir and wood savings. The air velocity, water flow rate and pad thickness was kept 11.6 ms?1, 3lpm and 100 mm for all the pad materials. During the tests outside air conditions were 28°C to 35°C and 33-67% relative humidity. The study was taken to compare the local cheaply available pads with commercially pads. Average drop in temperature was 8°C and 9.75°C was observed with Celdek and wood wool respectively. While coconut coir and wood saving pads showed temperature drop of 3.5°C and 3.25°C respectively. The percentage drop in temperature with CELdek and wood wool was 40% and 43% higher as compared to wood savings and coconut coir respectively. The RH inside the storage chamber was maintained above 80% in all pads.

 References

[1] Abdollah M., Hamid R. S., Mohammed L., Seyedmehdi S. and Hamid B., 2011. ?Investigating the performance of cellulosic evaporative cooling pads Energy Conversion, and Management, vol. 52(7), pp: 2598–2603.
[2] Ahmed E. M., Abaas O., Ahmed M., Ismail M. R., 2011. ?Performance evaluation of three different types of local evaporative cooling pads in greenhouses in Sudan, Saudi Journal of Biological Sciences, vol. 18(1), pp: 45-51.
[3] Al-Massoum A., Haffar I., Ahmed M. H., 1998. ?A similitude model for testing greenhouse evaporative cooling pads under the hot-arid conditions of the U.A.E. Crop Models in Protected Cultivation. (Marcelis LFM, ed), Acta Horticulturae 456 ISHS, 329–337.
[4] Bucklin R. A., Henley R.W., McConnell, D. B., 1993. ?Fan and Pad Greenhouse Evaporative Cooling Systems. University of Florida, Florida Cooperative Extension Service, Circular 1135.
[5] Dzivama A.U., Bindir U. B. Aboaba F.O., 1999.Evaluation of pad materials in construction of active evaporative cooler for stroge of fruits and vegetables in arid environments. Agricultural Mechanization in Asia, Africa and Latin America, AMA, vol.30(3), 51–55.
[6] Faleh Al-Sulaiman, 2002.?Evaluation of the performance of local fibers in evaporative cooling Energy conversion and Management, vol. (43), pp: 2267–2273.
[7] Gunhan T, Demir V, Yagcioglu A.K., 2007. ?Evaluation of the suitability of some local materials as cooling pad. Biosystems Eng ;vol. 96(3), pp:369–77.
[8] Jain J.K., Hindoliya D.A., 2011. ?Experimental performance of new evaporative cooling pad materials , Sustainable Cities and Society, vol. 1, pp: 252– 256.
[9] Kulkarni R.K., Rajput S.P.S., 2011. ?Comparative performance of evaporative cooling pads of alternative materials, International Journal of Advance Engineering Sciences and Technologies, vol. 10, pp: 239 – 244.
[10] Kulkarni M. M., Vijaykumar K. N., Jadav N. A., Bhor M. J., Shinde S S., 2015. ?Ëxperimental Performance Evaluatiom of New Cooling Pad Material for Direct Evaporating Cooling for Pune Summer Conditions, International Journal of Engineering Trends and Technology, Vol. 22 (6), pp: 281-287.
[11] Liao C.M., Chiu K.H., 2002. ?Wind tunnel modelling the system performance of alternative evaporative cooling pads in Taiwan Region. Building and Environment, vol. 37, 177–187.
[12] Liao C.M., Singh S., Wang T. S., 1998. ?Characterizing the performance of alternative evaporative cooling pad media in thermal environmental control applications. Journal of Environmental Science and Health, Part A—Toxic/Hazardous Substances & Environmental Engineering, vol. 33(7), 1391–1417.
[13] Maurya R., Shrivastava, N. and Shrivastava, V., 2014. ?Performance Evaluation of Alternative Evaporative Cooling Media, International Journal of Scientific & Engineering Research, Vol. 5 (10), pp: 676- 684.
[14] Mekonnen A., 1996. ?Effectiveness study of local materials as cooling media for shelters in hot climates. Agricultural Mechanization in Asia, Africa and Latin America, AMA, vol. 27(2), 64–66.
[15] Shrivastava, K., Deshmukh D. and Rawlani, M. V., 2014. ?Experimental analysis of coconut coir pad evaporative cooler, International Journal of Innovative Research in Science, Engineering and Technology, vol.3 (1), pp: 8346-8351.
[16] Waghchore R. K., Jumde M. R., Somwanshi A.H., 2013. ?Advance Cooling and Heating System for Cabinet, International Journal of Engineering Trends and Technology, vol.4(4),pp: 734- 738.

Keywords
Evaporative cooling, Saturation Efficiency, Relative Humidity, Wood Savings, Coconut Coir.