Effect of Shear Wall Area on Seismic Bheavior of Multisoried Builiding Tube in Tube Structure

  IJETT-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2017 by IJETT Journal
Volume-44 Number-4
Year of Publication : 2017
Authors : Tanneeru Sreevalli, N.Harika Priya
DOI :  10.14445/22315381/IJETT-V44P240

Citation 

Tanneeru Sreevalli, N.Harika Priya "Effect of Shear Wall Area on Seismic Bheavior of Multisoried Builiding Tube in Tube Structure", International Journal of Engineering Trends and Technology (IJETT), V44(4),202-210 February 2017. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group

Abstract
The advances in three-dimensional structural analysis and computing resources have allowed the efficient and safe design of taller structures. Tubular structures are common structural system for tall buildings over past few years. The tubular structures are of different types in which tube in tube structures are more suitable for high rise buildings. A tube in tube structure is formed by outer framed tube and inner core tube connected by floor slab. It is act like a huge tube (i.e. Peripheral tube) with a smaller tube (i.e., core tube) in middle of it. The load is transfer between these two tubes. In which a strong center tube of high strength concrete is the main load carrying structure. Presence of shear walls imparts a large stiffness to the lateral force resisting system of the RC building. One of the major parameters influencing the seismic behavior of shear wall frame buildings is the shear wall area ratio. Thus an analytical study is performed to evaluate the effect of Shear Wall Area to floor area ratio (SWA/FA %) on the seismic behavior of multistoried RC structures. For this purpose, 30 stories with SWA/FA % is considered.Then, the behavior of these building models under earthquake loading is examined by carrying out Static and Response Spectrum Analysis using structural analysis software E-TABS. Static and Response Spectrum Analysis is done according to seismic code IS 1893:2002.

 References

1. ACI 318 (2008). Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (318R-08). American Concrete Institute: Farmington Hills, MI.
2. Coull A and Abu El Magd SA (1980). Analysis of Wide-flanged Shear wall Structures. Reinforced concrete structures subjected to wind and earthquake forces: ACI special publication 63, Paper No. SP63-23, Concrete Institute, Detroit, MI: 575–607.
3. Coull A and Ahmed AA (1978). Deflections of framed-tube structures. Journal of Structural Engineering, ASCE 104(5) 857–862.
4. ETABS (1989). Three dimensional analysis of building system. Computers and Structures, Berkeley, USA.
5. Foutch DA and Chang PC (1982). A shear lag anomaly. Journal of Structural Engineering, ASCE 108(ST7) 1653–1657.
6. Kristek V and Bauer K (1993). Stress distribution in front columns of high rise buildings. ASCE Journal of Structural Engineering 115(5) 1326–1337.
7. Kwan AKH (1994). Simple method for approximate analysis of framed tube structures. Journal of Structural Engineering, ASCE 120(4) 1221–1239.
8. Kwan AKH (1996). Shear lag in shear/core walls. Journal of Structural Engineering, ASCE 122(9) 1097–1104.
9. Kwan M (1996). Shear lag in shear/core walls. ASCE Journal of Structural Engineering 122(9) 1097–1104.
10. Lee KK (1999). Orthotropic box beam analogy for analysis of framed tube structures with multiple internal tubes. PhD Thesis, Griffith University, Nathan, Queensland.
11. Lee KK, Lee LH and Lee EJ (2002). Prediction of shear-lag effects in framed-tube structures with internal tube(s). The Structural Design of Tall Buildings 11 73–92.
12. Singh Y and Nagpal K (1994). Negative shear lag in framed-tube buildings. ASCE Journal of Structural Engineering 120(11) 3105–3121.
13. J. J, Connor and C. C. Pouangare “Simple model for design of framed-tube “ ASCE Journal of Structural Engineering, Vol. 117, No. 12,December, 1991.
14. M. R. Jahanshahi, R. Rahgozar, M. Malekinejad “ A simple approach to static analysis of tall buildings with a combined tube-in tube and outrigger-belt truss system subjected to lateral loading “ Ije TransactionsA: Basics Vol. 25, No. 3, July 2012.
15. Kang-Kun Lee, Yee-Chaye Loo, Hong Guan “Simple Analysis of Framed-Tube Structures with Multiple Internal Tubes” Journal of Structural Engineering, Vol. 127, No. 4, April, 2001.
16. Myoungsu Shin1, Thomas H.-K. Kang ,James M. LaFave and Jacob S. Grossman “Design and behavior of a reinforced concrete high-rise tube building with belt walls” Struct. Design Tall Spec. Build. 2010.
17. Mir M. Ali “Performance characteristic of tall framed tube buildings in seismic zones” Eleventh World Conference Of Earthquake Engg 1996.
18. Wang Hi Bo, Shen Pu Sheng “ Nonlinear seismic response analysis of reinforced concrete tube in tube structures” J Cent South Univ Technol Vol 12 October 2005woln Pu-Shengj. CENT. SOUTH UNIV. TECHNOL.

Keywords
Static and Response Spectrum Analysis is done according to seismic code IS 1893:2002.