CFD analysis of solar air heater duct with rectangular rib surface

  ijett-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2013 by IJETT Journal
Volume-4 Issue-7                      
Year of Publication : 2013
Authors : Surjeet Singh Rajpoot , Dinesh Kumar Koli

Citation 

Surjeet Singh Rajpoot , Dinesh Kumar Koli. "CFD analysis of solar air heater duct with rectangular rib surface". International Journal of Engineering Trends and Technology (IJETT). V4(7):3006-3011 Jul 2013. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group.

Abstract

This paper presents the study of heat transfer in a rectangular duct of a solar air h eater having Rectangular rib with roughness on the absorber plate surface by using Computational Fluid Dynamics (CFD) and the effect on the surface heat transfer coefficient was investigated. The computations based on the finite volume method with the SIMP LE algorithm have been conducted for the air flow in terms of Reynolds numbers ranging from 3000 - 18000. A commercial finite volume package ANSYS FLUENT 6.3 and GAMBIT is used to analyze and visualize the nature of the flow across the duct of a solar air he ater. CFD simulation results were found to be in good agreement with experimental results and with the standard theoretical approaches. It has been found that the temperature is increasing at the outlet side and it reaches to maximum due to the rectangular shape of the duct.

References

[1] Jaurker, A.R. Saini, J.S. and Gandhi, B.K., (2006). Heat transfer and friction characteristics of rectangular solar air heater duct using rib - grooved artificial roughness, Solar Energy , 80, pp. 895 – 907.
[2] Karmare, S.V. and Tikekar, A.N., (2007). Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs, Int. Journal of Heat Mass Transfer , 50, pp. 4342 – 4351.
[3] Karwa, R. Solanki, S.C. and Saini, J.S., (1999) Heat transfer coefficient and friction factor correlations for the transitional flow regimes in rib - roughened rectangular duct, Int. Journal of Heat Mass Transfer, 42, pp. 1597 - 1615.
[4] Karwa, R. Solanki, S.C. and Saini, J.S., (2001). Thermohydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plate, Energy , 26, pp. 161 – 176.
[5] Karwa, R., (2003). Experimental studies of augmented heat transfer and friction in asymmetrically heated rectangular ducts with ribs on the heated wall in transverse, inclined, V - continuous and V - discrete pattern, Int. Comm. Heat Ma ss Transfer , 30, pp. 241 – 250.
[6] Kumar, S. and Saini, R.P., (2009). CFD based performance analysis of a solar air heater duct provided with artificial roughness , Renewable Energy , 34, pp. 1285 – 1291.
[7] Laohalertdecha, S. Naphon, p. and Wongwises, S., (2007). A review of electro hydrodynamic enhancement of heat transfer, Renewable and Sustainable Energy Reviews, 11, pp. 858 – 876.
[8] Layek, A. Saini, J.S. and Solanki, S.C., (2007). Heat transfer and friction characteristics for artificially roughe ned duct with compound turbulators, International Journal of Heat and Mass Transfer, 50, pp. 4845 – 4854.
[9] Alok Chaube, P.K. Sahoo, Renewable Energy 31 (2006) Analysis of heat transfer augmentation and flow characteristics due to rib roughness over abso rber plate of a solar air heater.

Keywords
Solar Air Heater, Heat transfer, CFD.