Optimum Design & FEA of Tibia Fractured Composite Bone Plate

  IJETT-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2018 by IJETT Journal
Volume-57 Number-2
Year of Publication : 2018
Authors : M.S.El-Sayed, Ahmed S. A. AbouTaleb, M.FahmyAly
DOI :  10.14445/22315381/IJETT-V57P219

Citation 

M.S.El-Sayed, Ahmed S. A. AbouTaleb, M.FahmyAly "Optimum Design & FEA of Tibia Fractured Composite Bone Plate", International Journal of Engineering Trends and Technology (IJETT), V57(2),89-97 March 2018. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group

Abstract
To evaluate the optimum design of laminated glass-fiberPolyvinyl Chloride (PVC) - matrix composite bone plate based on genetic algorithm (GA). This plate used to fix tibial fractures.

Reference
[1] Spivak JM, Zuckerman JD,Kummer FJ, Frankel VH. 1991. ?Fatigue failure of the sliding screw in hip fracture fixation: a report of three cases?. J Orthop Trauma, 5:325–31.
[2] SemihBenli, SamiAksoy, HasanHav?tc?oglu, MuminKucuk. 2008.?Evaluation of bone plate with low-stiffness material in terms of stress distribution?.
[3] Tulner SA, Strackee SD, Kloen P. 2012 ?Metaphyseal locking compression plate as an external fixator for the distal tibia?. Int Orthop;36(9):1923–7.
[4] Ma CH, Wu CH, Tu YK, Lin TS. 2013. ?Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures–clinical outcome and a finite element study?. Injury.44(8):1097–101.
[5] Zhou Y, Wang Y, Liu L, Zhou Z, Cao X. 2015. ?Locking compression plate as an external fixator in the treatment of closed distal tibial fractures?.IntOrthop.39(11):2227–37.
[6] Zhang J, Ebraheim NA, Li M, He X, Liu J, Zhu L, Yu Y, Siddiqui S. 2015. ?External fixation using a locking plate: a reliable way in treating distal tibial fractures?. J Orthop Trauma. 29(11):e454–8.
[7] Fujihara K, Hung ZM. 2003. ?Performance study of braid carbon/PEEK composite compression bone plates?. Biomaterials;23:2661–7.
[8] Saidpour SH. 2006. ?Assessment of carbon fiber composite fracture fixation plate using finite element analysis?. Ann Biomed Eng;34:1157–63.
[9] Ramakrishna K, Sridhar I, Sivashanker S, Khong KS, Ghista DN. 2004. ?Design of fracture fixation plate for necessary and sufficient bone stress shielding?. JSME Int J C – MechSyst;47(4):1086–94.
[10] Fouad H. 2010. ?Effects of the bone–plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone?. Med EngPhys;32(7):783– 9.
[11] Terjesen T, Apalset K. 1988. ?The influence of different degrees of stiffness of fixation plates on experimental bone healing?. J Orthopaed Res;6(2):293–9.
[12] Ganesh VK, Ramakrishna K, Ghista DN. 2005. ?Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates?. Biomed Eng Online;4:46.
[13] Zhang, L., Miramini, S., Mendis, P., Richardson, M., Pirpiris, M. and Oloyede, K. 2013. ?The effects of flexible fixation on earlystage bone fracture healing,? Int. J. Aerosp.Lightweight Struct.3(2), 181–189.
[14] Miramini, S., Zhang, L., Richardson, M., Mendis, P. and Ebeling, P. R. 2016a ?Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures,? Med. Eng. Phys. 38(10), 1100–1108.
[15] Miramini, S., Zhang, L., Richardson, M., Mendis, P., Oloyede, A. and Ebeling, P. 2016b. ?The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation,? Aust. Phys. Eng. Sci. Med. 39(1), 123– 133.
[16] Zhang, L., Miramini, S., Richardson, M., Ebeling, P., Little, D., Yang, Y. and Huang, Z.2017. ?Computational modelling of bone fracture healing under partial weight-bearing exercise,? Med. Eng. Phys. 42, 65–72.
[17] Miramini, S., Zhang, L., Richardson, M., Pirpiris, M., Mendis, P., Oloyede, K. and Edwards, G. 2015. ?Computational simulation of the early stage of bone healing under different configurations of locking compression plates.?Comput.Methods Biomech.Biomed. Eng. 18(8), 900–913.
[18] Miramini, S., Zhang, L. H., Richardson, M. and Mendis, P. 2014 ?Computational simulation of mechanical microenvironment of early stage of bone healing under locking compression plate with dynamic locking screws.? Appl. Mech. Mater. 553, 281–286.
[19] Chaya A, Yoshizawa S, Verdelis K, Noorani S, Costello BJ, Sfeir C. 2015. ?Fracture Healing Using Degradable Magnesium Fixation Plates and Screws?, Journal of Oral and Maxillofacial Surgery, 73(2):295-305.
[20] Amy Chayas et al. 2015 ?In vivo study of magnesium plate and screw degradation and bone fracture healing?, ActaBiomaterialia, Volume 18, Pages 262–269
[21] Ramakrishna S, Mayer J, Wintermantel E. 2001. ?Biomedical application of polymer composite materials?: a review. Compos SciTechnol;61:1189–224.
[22] Kanchanomai C, Phiphobmongkol V. 2008. ?Fatigue failure of an orthopedic implant – a locking compression plate?.Eng Fail Anal;15:521–30.
[23] Tayton K, Bradley J. 1983. ?How stiff should semi-rigid fixation of the human tibia be – a clue to the answer?. J Bone Joint Surg Br;65(3):312–5.
[24] Tayton K, Johnsonnurse C, Mckibbin B, Bradley J, Hastings G. 1982. ?The use of semi-rigid carbon-fiber-reinforced plastic plates for fixation of human fractures – results of preliminary trials?. J Bone Joint Surg Br;64(1):105–11.
[25] Takiron Co. 1999. ?Bioresorbable devices made of forged composites of Ha/PLLA part I. basic characteristics?. Biomaterials;20:859–77.
[26] Veerabagu, S., Fujihara, K., Dasari, G.R., Ramakrishna, S., 2003. ?Strain distribution analysis of braided composite bone plates?. Composites Science and Technology 62, 427–435.
[27]Ali, .S.,French,T.A.,Hastings,G.W.,Rae,T.,Rushton,N.,Ross,E. R.,1990. ?Carbon fibre composite bone plates: development,evaluation and early clinical experience? .Journal of Bone and Joint Surgery—British Volume72,586–591.
[28] Fujihara, K., Huang, Z.H., Ramakrishna, S., Satknanantham, K., Hamada, H., 2004. ?Feasibility of knitted carbon/PEEK composites for orthopedic bone plates?. Biomaterials 25, 3877– 3885.
[29]Ya-Kui Zhang, Hung-Wen Wei, Kang-Ping Lin, Wen-Chuan Chen, Cheng-Lun Tsai, Kun-Jhih Lin, 2016. ?Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis?. Journal of injury;6632:1–5.
[30] Muhammad HanifRamlee, Mohammed Rafiq Abdul Kadir, Malliga Raman Muralib, Tunku Kamarul. 2014 ?Biomechanical evaluation of two commonly used external fixators in the treatment of open subtalar dislocation—A finite element analysis?.Jorurnal of medical Eng.&physics;1358-1368.
[31] Mehboob H, Son DS, Chang SH. 2013 ?Evaluation of healing performance of biodegradable composite bone plates for a simulated fractured tibia model by finite element analysis?. Compos SciTechnol;80:55–65.
[32] Samiezadeh, S., Avval, P.T., Fawaz, Z., Bougherara, H. 2015 ?On optimization of a composite bone plate using the selective stress shielding approach?. J. Mech. Behav. Biomed. Mater;43, 138–153.
[33] Park SW, Yoo SH, Lee JE, Chang SH. 2012 ?Material characterization of glass/polypropylene composite bone plates according to the forming condition and performance evaluation under a simulated human body environment?. J Korean Soc Compos Mater;23:1101–1108.
[34]Mehboob H, Son DS, Chang SH. 2015 ?Optimal design of a functionally graded biodegradable composite bone plate by using the Taguchi method and finite element analysis?. Compos SciTechnol;110:167–173.
[35]N.D.Chakladarn,L.T.Harper,A.J.Parsons. 2016 ?Optimisation of composite bone plates for ulnar transverse fractures?. J. Mech. Behav. Biomed. Mater;57, 334–346.
[36] Ahmed S. A. AbouTaleb, Basman N. El-Hadid, Badr S. N. Azzam, and Sayed M. Metwalli. 2012. ?Optimum design of horizontal axis wind turbine composite blade structure?.
[37] K. Deb, 2002 "A fast and elitist multi-objective genetic algorithm NSGA-II", IEEE Trans Evolution Computer, Vol. 6, Issue 2, PP 182 – 196.
[38] J. N. Reddy, 2004 ?Mechanics of laminated composite plates and shells theory and analysis?, CRC Press,.
[39] Abraham, A., Jain, L. and Goldberg, R. (Eds), 2005 ?Evolutionary Multi-objective Optimization: Theoretical Advances and Applications?, pp. 273-300,.
[40] Lin, C-M., Gen, M. 2008, ?Multi-Criteria Human Resource Allocation for Solving Multistage Combinatorial Optimization Problems Using Multi-Objective Hybrid Genetic Algorithm?, Expert Systems with Applications, Vol.34, pp.2480-2490.
[41] K. Deb, 2000 ?An efficient constraint handling method for genetic algorithms", Computer Meth, Applied Mechanics Eng., Vol. 186, PP 311 – 328.
[42] M. O. Kaman, N. Celik, S. Karakuzu. 2014 ?Numerical stress analysis of the plates used to treat the tibia bone fracture", Applied Mathematics and Physics, Vol. 2, PP 304 – 309,.
[43] Hyun-Jun Kim, Suk-Hun Kim, Seung-Hwan Chang. 2011 ?Bio-mechanical analysis of a fractured tibia with composite bone plates according to the diaphyseal oblique fracture angle", composites, part b. 42, PP 666 – 67

keywords
Bone plate, Composite material, Genetic algorithm, and Optimization, FEA.