Zuriman Anthony. "A Simple Method For Operating The Three-Phase Induction Motor On Single Phase Supply (For Wye Connection Standard)". International Journal of Engineering Trends and Technology (IJETT). V5(1):13-16 Nov 2013. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group

Abstract

This research is purposed to establish a new method is good and simple to operate the 3-phase induction motor on single-phase power by using the capacitors. The research was conducted at the Laboratory of the Electrical Engineering of the Padang Institute of Technology. The object used in this research was the 3-phase induction motor that has the standard of 2 HP, 380 V, Wye connection, 4 pole, 50 Hz, 1400 RPM, 3.6 A. The results of this research showed that the method could work well to control the motor to operate properly to load 85% of the 3-phase rating. In general, the motor has a better performance when operating on 1-phase power system in all load cases (low and high load). The motor could operate with power factor close to unity, higher speed and better efficiency. The motor operated with higher current harmonic distortion at low loads but lower current harmonic distortion at high loads. Therefore, it is very good to operate the motor at high load up to 85% of the 3-phase rating.

References

[1] Anthony, Z, Tumiran, and Berahim, H, “The performance of the 3-phase induction motor while operating on single phase supply (Kinerja pengoperasian motor induksi 3-fasa pada sistem tenaga 1-fasa dengan menggunakan kapasitor)”, Journal of Teknosain UGM , vol. 16 no. 1, pp. 1-12, Jan. 2003.
[2] Anthony, Z, 2004, “Analysis of the run capacitor circuit of the SemihexTM motor’s method (Analisa kapasitor jalan pada metode SemihexTM motor), in Proc. SNVMS 2004 Conference, 2004, pp. 637-641.
[3] Anthony, Z, “The design of the start capacitor circuit to operate the 3-phase induction motors on single phase power (Perencanaan kapasitor start untuk mengoperasikan motor induksi 3-fase pada sistem tenaga 1-fase)”, Journal of Momentum ITP , vol. 2 no. 2, pp. 9-13, Aug. 2004.
[4] Anthony Z, “The Dual function control system design for operating the 3-phase induction motor (Perancangan sistem kendali dual fungsi pengoperasian motor induksi 3-fasa)”, Journal of Momentum ITP, vol. 3 no. 2, pp. 58-63, Aug. 2005.
[5] Anthony, Z, “The design of the run capacitor circuit to operate the 3-phase induction motors on single phase power (Perancangan kapasitor jalan untuk pengoperasian motor induksi 3-fasa pada sistem tenaga 1-fasa)”, Journal of Teknik Elektro UK Petra, vol. 8 no. 1, pp. 46-51, March 2008.
[6] Anthony, Z, “Capacitor bank Effect to the starting current of the 3-phase induction motor (Pengaruh penggunaan kapasitor perbaikan faktor daya terhadap arus start motor induksi 3-fasa), Journal of Teknik Elektro ITP, vol. 2 no. 1, pp. 26 – 32, Jan. 2013.
[7] Badr M.A, Alolah A.I and Halim Abdul M.A, “A capacitor start three phase induction motor”, IEEE transaction on energy conversion, vol. 10 no. 4, pp. 675-680, Dec. 1995.
[8] Huang H, Fuchs EF and White J.C, “Optimal placement of the run capacitor in single phase induction motor designs”, IEEE transactions on energy conversion, Vol. 3, no. 3, pp. 647-652, Sep. 1988.
[9] Scheda, F. A, Operating 3-phase motors on 1-phase power, EC&M, January 1985, pp. 40-41.
[10] Smith, O.J, “Large Low-Cost Single-phase SemihexTM Motor “, IEEE Trans. on Energy Conversion, vol. 14 no. 4, pp. 1353-1358, 1999,.

Keywords
Capacitor circuit, capacitance of the start capacitor, capacitance of the run capacitor, Apparent power of the motor, power factor.