CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct

  ijett-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2013 by IJETT Journal
Volume-4 Issue-9                      
Year of Publication : 2013
Authors : Suman Saurav , V.N.Bartaria

Citation 

Suman Saurav , V.N.Bartaria. "CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct". International Journal of Engineering Trends and Technology (IJETT). V4(9):3936-3944 Sep 2013. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group.

Abstract

The thermal performance of solar air heater is generally poor due to low heat transfer coefficient between the absorber plate and air flowing in the duct. In order to improve the thermal performance artificial roughness is provided on the underside of a bsorber plate due to which turbulence is created in the heat transfer zone and ultimately performance of solar air heater improves considerably. This paper presents the study of heat transfer in a rectangular duct of a solar air heater having triangular ri b roughness on the absorber plate by using Computational Fluid Dynamics (CFD). The effect of Reynolds number on Nusselt number was investigated to study the heat transfer, friction factor and flow characteristics in a solar air heater having triangular rib roughness on the absorber plate. The computations based on the finite volume method with the SIMPLE algorithm have been conducted for the air flow in terms of Reynolds numbers ranging from 4000 – 20000 and p/e (4 to 20) has been carried out with k - ? turbu lence model is selected by comparing the predictions of different turbulence models with experimental results available in various literature. In present work computational fluid dynamics software (Fluent 6.3 Solver) has been used for simulation. Fluid flo w (FLUENT) module has been used in present work. Fluid flow (FLUENT) module predicts the outlet temperature, velocity, flow behavior to great accuracy due to application of thermal loading on the work piece. It has been found that the nusselt number increa ses with increase in Reynolds number. Maximum value of nusselt number friction factor is obtained at relative roughness pitch of 4.

References

[1] Momin A - M.E., Saini J.S., Solanki S.C. Heat transfer and friction in solar air heater duct with Vshaped rib roughness on absorber plate. International J. of Heat and Mass Transfer . 2001, 45(16), 3383 - 3396.
[2] Karwa R., Solanki S.C., and Saini J.S. Thermo - hydraulic performance of solar air heaters having integral chamfered rib - groove roughness on absorber plates. Energy. 2000, 26,161 - 176.
[3] Bhagoria J.L., Saini J.S. and Solanki S .C.,Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate, Renew.Ene. , 25 (3), 341 - 369, (2001).
[4] Sahu M.M. and Bhagoria J.L., Augmentation of heat transfer coefficient by using 90° broken transverse ribs on absorber plate of solar air heater, Renew. Ene. , 30 (13) 2057 - 2073, (2005).
[5] Jaurker A.R., Saini J.S., and Gandhi B.K. Heat transfer coeffic ient and friction characteristics ofrectangular solar air heater duct using rib - grooved artificial roughness. Solar Energy. 2005, 80(8),895 - 907.
[6] Varun, Saini R.P., Singal S.K. Investigation of thermal performance of solar air heater havingroughness ele ments as a combination of inclined and transverse ribs on absorber Plate. RenewableEnergy. 2007, 33(6), 1398 - 1405.
[7] Aharwal K.R, Gandhi B.K, Saini J.S. Heat transfer and friction characteristics of solar air heater duct having gap in integral inclined c ontinuous ribs on absorber plate. International Journal of Heat andMass Transfer. Renewable Energy 33 (2007) 585 – 596.
[8] Karmare S.V., Tikekar A.N. Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs. Interna tional Journal of Heat and Mass Transfer. S.V. Karmare, A.N. Tikekar / Solar Energy 83 (2008) 6 – 13.
[9] Layek A., Saini J.S., and Solanki S.C. Heat transfer and friction characteristics for artificially roughened ducts with compound turbulators. Internatio nal Journal of Heat and Mass Transfer. A. Layek et al. / Renewable Energy 34 (2008) 1292 – 1298.
[10] Saini S.K., Saini R.P., “Development of Correlations for Nusselt Number and Friction Factor for Solar Air Heater with Roughened Duct Having Arc Shaped Wire as Artificial Roughness”, Solar Energy, 2008, vol.82, pp.1118 - 1130.
[11] Kumar Thakur Sanjay,Thakur N.S, Kumar Anoop, Mittal Vijay, Heat Transfer and Friction Factor Correlations for Rectangular Solar Air Heater Duct Having 60° Inclined Continuous Discrete Rib Arrangement, British Journal of Applied Science & Technology, 1(3):67 - 93, 2011.
[12] Kumar Thakur Sanjay,Thakur N.S, Kumar Anoop, Mittal Vijay, “Use of Artificial Roughness to Enhance Heat Transfer in Solar Air Heaters – A Review”, Energy, 2010, vol.2 1, pp.35 - 51.
[13] Choudhary sachin,Varun,Chouhan Kumar Manish Heat transfer and friction factor characteristics using continuous M shape ribs turbulators International Journal of Energy and Environment (IJEE), Volume 3, Issue 1, 2012, pp.33 - 48.
[14]Lanjewa r.A.M,Bhagoria.J.L,Sarviya.R.M Thermohydaulic Performance Of Solar Air Collector Using W - Shaped Artificial Roughness Journal of Environmental Research And Development Vol. 6 No. 3A, Jan - March 2012.
[15] A.K.Patil, J.S.Saini, K.Kumar A Comprehensive Revie w on Roughness Geometries and Investigation Techniques Used in Artificially Roughened Solar Air Heaters International Journal of Renewable Energy Resarch, Vol.2, No.1, 2012.
[16] Saini R.P., Verma J., “Heat Transfer and Friction Correlations for a Duct Hav ing Dimple Shape Artificial Roughness for Solar Air Heater”, Energy, 2008, vol.33, pp.1277 - 1287.
[17] Bopche S.B., Tandale M.S., “Experimental Investigation on Heat Transfer and Friction Characteristics of a Turbulator Roughened Solar Air Heater Duct”, Int ernational Journal of Heat and Mass Transfer, 2009, vol.52, pp.2834 - 2848.
[18] Varun, Saini R.P., Singal S.K., “A Review on Roughness Geometry Used in Solar Air Heaters”, Solar Energy, 2007, vol.81, pp. 1340 - 1350.
[19] Yadav AS, Bhagoria JL. “Heat transfer and fluid flow analysis of solar air heater:a review of CFD approach”, Renewable and Sustainable Energy Reviews 2013;23:60e79.
[20] Chaube A, Sahoo PK, Solanki SC. “Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater”,Renewable Energy 2006;31:317e31.
[21] Yadav AS et al. “A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness on The Absorber Plate”, Int.J.ChemTech Res.2013, 5(2).
[22] Yadav AS et al. “ A CFD (computatio nal fluid dynamics) based heat transfer and fluid flow analysis of a solar air heater provided with circular transverse wire rib roughness on the absorber plate” , Energy 55 (2013) 1127e1142.
[23] Sharma A. K. and Thakur N.S., “CFD based Fluid Flow and Hea t Transfer Analysis of a V - Shaped Roughened Surface Solar Air Heater”, International Journal of Engineering Science and Technology, 2012, 4(5), 2115 - 2121.
[24] Karmare S. V. andTikekar A. N. “Analysis of Fluid Flow and Heat Transfer in a Rib Grit Roughened Surface Solar Air Heater using CFD”,SolarEnergy, 2010, 84 (3), 409 - 417.
[25] Kumar S. andSaini, R. P. “CFD based Performance Analysis of a Solar Air Heater Duct Provided with Artificial Roughness”, Renewable Energy, 2009, 34 (5), 1285 - 1291.
[26] Rai G.D., “Non Conventional Energy Sources”, 4th ed., Khanna Publishers, 2010.
[27] Shaw C.T., “ Using Computational Fluid Dynamics”, Prentice Hall, 1992.
[28] Cebeci Tuncer et.al,” Computational Fluid Dynamics for Engineers” ’ © Horizons Publishing Inc., Long Beach, California 2005.
[29] Versteeg H.K.et.al,” An introduction to computational fluid dynamics, the finite volume method”, Longman group limited 1995.
[30] Nayak Satyapraksh et.al.” heat transfer analysis of rectangular roughness rib in solar air heater duct by computational fluid dynamics (cfd)”, International Journal of Advanced Research in Science, Engineering and Technology, Vol.01, Issue 03, pp. 25 - 30.
[31] Nayak Satyapraksh et.al. “heat transfer and fluid flow analysis of roughness rib in solar air heat er duct by computational fluid dynamics (cfd) simulation”, International Journal of Advanced Research in Science, Engineering and Technology, Vol.01, Issue 03, pp . 15 - 20.

Keywords