Pre Engineered Building systems have become a great
alternative to conventional steel buildings due to its advantages
like faster construction, easy fabrication and economy. In this
contest more researches on pre engineering buildings (PEB) are
being done to make it more efficient. In this paper Pre
Engineered Buildings (PEB) with different roof shapes such as
Curved, Pitched & Mono slope have been compared. The study
involves an industrial building of length 77.5m and width 25m,
with different shapes of roof system. Analysis and design are
done using STAAD PRO V8i and results are compared, to
understand the behaviour of different roof shapes of Pre
Engineered Building.
References
[1] IS: 875 (Part 1) – 1987: Code of Practice for
Design Loads (Other Than Earthquake) for Buildings and
Structures- Dead Loads.
[2]IS: 875 (Part 2) - 1987: Code of Practice for
Design Loads (Other Than Earthquake) for Buildings And
Structures- Live Loads
[3]IS: 875 (Part 3) - 1987: Code of Practice for
Design Loads (Other Than Earthquake) for Buildings and
Structures- Wind Loads.
[4] Dr. N. Subramanian, “Design of Steel Structures”.
[5] IS: 800 - 2007:- General Construction In Steel- Code of
Practice.
[6] Kanakambara Rao et al. “Design of Pre-Engineered
steel structures building and to choose a material which offers
low cost, strength, durability, design flexibility and
recyclability”, International Journal of Engineering Research
and Applications (IJERA), Vol. 2, Issue 2, April 2012, pp:
267-272.
[7] Kulkarni A.V., “Comparative Study of Analysis and
Design of Pre-Engineered Buildings and Conventional Frames
and various advantages of PEB’s”, IOSR journal of
mechanical and civil engineering, Volume 5, Issue 3, Jan. –
Feb. 2013, pp: 47-53.
[8] Jatin D.Thakar, P.G. Patel, “Comparative Study of Pre-
Engineered Steel Structure by varying width of Structure”,
International Journal of Advanced Engineering Technology,
Volume IV, Issue III, sept 2013, pp: 56-62.
[9] Pradeep V , Papa Rao G, "Comparative Study of Pre
Engineered and Conventional Industrial Building",
International Journal of Engineering Trends and Technology,
Volume IX, Number 1, Mar 2014, pp: 1-6.
Keywords
Pre Engineered Building, STAAD Pro V8i, Curved