Seismic Response of Rc Frame Building With Soft Storey At Different Floor Levels

  IJETT-book-cover  International Journal of Engineering Trends and Technology (IJETT)          
  
© 2016 by IJETT Journal
Volume-42 Number-4
Year of Publication : 2016
Authors : K.Vamsi Satyanarayana, Vinodh kumar
DOI :  10.14445/22315381/IJETT-V42P240

Citation 

K.Vamsi Satyanarayana, Vinodh kumar "Seismic Response of Rc Frame Building With Soft Storey At Different Floor Levels", International Journal of Engineering Trends and Technology (IJETT), V42(4),201-207 December 2016. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group

Abstract
Many multistorey buildings in India today have open first storey as an unavoidable feature. This is primarily being adopted to accommodate parking or reception lobbies in the first storeys. The upper storeys have brick infilled wall panels. Reinforced concrete (RC) frame buildings with masonry infill walls have been widely constructed for commercial and may effect .so by using to avoid lateral displacement and storey drift, stiffness of masonary infill, performance of soft storey building by using ETABS provided columns and adjacent infills at each corner of building at different floor levels at different zones.

 References

1. C.V.R.Murty, "Why Are Open Ground Storey Buildings Vulnerable in Earthquakes", Indian Institute of Technology Kanpur, Earthquake tip 21, December 2003.
2. D. B. Karwar and Dr. R. S. Londhe (2014), Performance of RC Framed Structure by Using Pushover Analysis, International Journal of Emerging Technology and Advanced Engineering.
3. Dhadde Santosh (2014), Evaluation and Strengthening of Soft Storey Building, International Journal of Ethics in Engineering & Management Education. 4. ETABS (Version 9.7) “ETABS User’s Manual Revision 9.7”
5. F. Demir and M. Sivri “Earthquake Response of Masonry Infilled Frames” ECAS2002 International Symposium on Structural and Earthquake Engineering, October 14, 2002, Middle East Technical University, Ankara, Turkey.
6. FEMA-273, (1997), NEHRP Guidelines for the Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington, D. C, October.
7. Goutam Mondal and S.K.Jain (2008),” Lateral Stiffness of Masonry Infilled RC Frame with Central Opening”, Earthquake Spectra, Vol. 24, N0.3, PP.701-723, Aug 2008.
8. Hiten L. Kheni,and Anuj K. Chandiwala(2014), Seismic Response of RC Building with Soft Stories, International Journal of Engineering Trends and Technology (IJETT) – Volume 10 Number 12 - Apr 2014.
9. IS-1893 2002 Indian Standard Criteria for Earthquake Resistant Design of Structures (part 1) BIS, New Delhi,
10. Jaswant N. Arlekar, Sudhir K. Jain and C.V.R. Murty, "Seismic zone Response of RC Frame Buildings with Soft First Storeys" Proceedings of the CBRI Golden Jubilee Conference on Natural Hazards in Urban Habitat, 1997,` New Delhi.
11. M. N. Fardis and T. B. Panagiotakos “Seismic Design and Response of Bare and Masonry-Infilled Reinforced Concrete Buildings” Journal of Earthquake Engineering, 1:3, pp.475-503, 1997.
12. M.Koti Reddy, D.S.Prakash Rao and A.R.Chandrasekaran, "Modeling of RC Frame Buildings with Soft Ground Storey", the Indian Concrete Journal, Volume 81, No. 10, October 2007.
13. Mainstone, R.J., (1971), “On the Stiffness and Strengths of Infilled Frames”, Proceedings of the Institution of Civil Engineers, Supplement IV, Paper No. 7360S, pp. 57-90.
14. Mr. D. Dhandapany (2014), Comparative Study of and Analysis of Earthquake G+5 Storey Building with RC Shear Wall, Int. J. Engineering Research and Advanced Technology,Vol 2 (3),167-171.
15. Murty,C.V.R., and Jain,S.K., (1996), “Draft IS:1893 Provisions on Seismic Design of Buildings,” Bureau of Indian Standards, New Delhi.
16. Perumal Pillial E.B., Govindan P.,? Structural Response Of Brick Infill In R.C Frames.?International Journal Of Structural?,vol.14, No 2, Dec 1994.
17. Rakshith Gowda K.R and Bhavani Shankar (2014), Seismic Analysis Comparison of Regular and Vertically Irregular RC Building with Soft Storey at Different Level, International Journal of Emerging Technologies and Engineering (IJETE).
18. Helou and Abdul Razzaq Touqan, "seismicBehaviour of RC Structures with Masonry Walls" An-Najah Univ. J. Res. (N.Sc.), Volume 22, 2008, pp 77-92.
19. Haque, Khan Mahmud Amanat, "Seismic zoneVulnerability of Columns of RC Framed Buildings with Soft Ground Floor" International Journal of Mathematical Models And Methods In Applied Sciences, Issue 3, Volume 2,2008, pp 364-371.
20. Suchita Hirde and Ganga Tepugade(2014), Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall, International Journal of Current Engineering and Technology E-ISSN 2277 – 4106, P-ISSN 2347 – 5161.
21. Takuya Nagae, Keiichiro Suita, Masayoshi Nakashima, "Performance Assessment for Reinforced Concrete Buildings with soft first stories" Annuals of Disas. Res.Inst,Kyoto.
22. Yong Lu, T. P. Tassios, G.-F. Zhang, and Elizabeth Vintzileou, "Seismic zone Response of Reinforced Concrete Frames with Strength and Stiffness Irregularities", ACI Structural Journal Technical, Volume 96, No. 2, March -April 1999, pp 221 -229.
23. Yong Lu "Comparative Study of Seismic zone Behaviour of Multistory Reinforced Concrete Framed Structures" Journal of Structural Engineering, Volume 128, No. 2, February 2002.

Keywords