Parametric Study of Flat Slab Building with Shear Wall at Different Location
Citation
Nitesh M. Patel, Anuj Chandiwala, Hitesh K. Dhameliya "Parametric Study of Flat Slab Building with Shear Wall at Different Location", International Journal of Engineering Trends and Technology (IJETT), V47(4),243-249 May 2017. ISSN:2231-5381. www.ijettjournal.org. published by seventh sense research group
Abstract
Flat slab is a reinforced concrete slab supported directly by concrete columns without the use of beams, column flares or drop panels. Flat slab system has been adopted in many buildings constructed recently taking advantage of the reduced floor height to meet the economical and architectural demands. However, In Multistoried structures the flat slab floor system has week resistance to lateral loads like wind and earthquake hence this paper is concerned to increase resistance of flat slab structure using shear wall at different location. In present work, 15 storied flat plate building have been modeled using software package “ETABS” for different earthquake zone i.e. Zone-3, Zone-4 and Zone-5 using static analysis (seismic coefficient method) and dynamic analysis (response spectrum method and time history method). Comparison maximum story displacement, maximum story drift, base shear, time period.
References
[1] Anuj Chandiwala, “Earthquake Analysis of Building Configuration with Different Position of Shear Wall” International journal of emerging technology and advanced engineering, ISSN 2250-2459, Volume 2, Issue 12, December 2012.
[2] Bhat S. M., Shenoy Premanad, N. A. Rao, “Earthquake behavior of building with and without shear walls”, IOSR journal of mechanical and civil engineering, PP 20-25, 2012.
[3] Dr. R. P. Rethaliya, Earthquake Engineering.
[4] Dr. R. P. Rethaliya, Structural Design-I (R.C.C).
[5] Fayazuddin Ahmed Syed, B. Dean Kumar, Y. Chandrasekhar, B.L.P. Swami, “Comparative analysis of flat plate multistoried frames with and without shear walls under wind loads” international journal of engineering and advanced technology (IJEAT) ISSN: 2249 – 8958, volume-2, issue-1, October 2012.
[6] IS: 13920-1993, “Ductile detailing of reinforced concrete structure subjected to seismic forces- code for practice (third re-print)”
[7] IS: 1893-2002, “Criteria for earthquake resistant design of structure (fifth revision)”
[8] IS: 456-2000, ”Plain and reinforced concrete-code for practice (4th edition)”
[9] K. G. Patwari1, L. G. Kalurkar, “Shear wall locations with flat slab and its effect on structure subjected to seismic effect for multistory building”, ISSN © 2016 IJESC, research article volume 6 issue no. 8.
[10] Miss Mrudul Kishor Burande, “Study of RC shear wall system in a multi-storied building and effect of shear wall on flat slab and two way slab” International organization of engineering research and development (IOERD), E-ISSN: 2455 ? 9075, Vol:1, Issue:4
[11] Sanjay P. N., Mahesh Prabhu K., Umesh S. S., “ Behavior of flat slab RCC structure under earthquake loading” International journal of engineering research and technology (IJERT), ISSN: 2278 ? 0181, Vol:3, Issue: 5, May ? 2014.
Keywords
Flat slab, Shear wall, ETABS, Response spectrum method, Time history method.